Fully Automated Multiplex Pathogen Molecular Diagnostic PCR System
- Point of origin
- China CE ISO13485 ISO9001 FDA
- Testing item
- Influenza A/B,RSV A/B,Influenza A virus H3,Parainfluenza virus 2,Coronavirus OC43
- Throughput
- 1~8 samples at the same time
- Application scenarios
- Outpatient emergency, lab,CDC
- Sample
- Whole blood, pre-diluted
P8000 is an innovative fully automated PCR system that utilizes magnetic bead-based nucleic acid extraction technology and real-time fluorescence PCR principles. It provides an efficient solution for nucleic acid extraction, in vitro amplification, and analysis in molecular diagnostics. The system performs fully automated operations including sample tube opening/closing, precise liquid handling, and system setup, offering an integrated nucleic acid testing experience.
Key Features
12.1-inch Intuitive Touch Screen
Offers a clear user interface and easy-to-use touch controls.
High Throughput Testing
Supports simultaneous testing of 8 samples with 4 fluorescent channels. One reagent can detect up to 45 target genes in a single sample.
Open System
Flexible to adapt to various reagents, providing more application possibilities.
One-Button Operation
Users can start the entire testing process with a single touch, achieving a “sample in—result out” fully automated process.
No Result Interpretation Needed
The system automatically interprets results, eliminating the need for manual reading and reducing human error.
Closed System
The closed design minimizes contamination risk, ensuring accuracy in the testing process.
Compact and Efficient
Integrates opening/closing of tubes, nucleic acid extraction, system setup, and nucleic acid detection into a single device. Touch screen operation allows for approximately 2 hours to complete testing for multiple pathogens.
User-Friendly Operation
The experimental preparation interface clearly shows the sample area, nucleic acid extraction area, and nucleic acid detection area. The software automatically recognizes the sample tube and reagent positions, providing alerts if there are placement errors. After loading samples and consumables, a single touch starts the experiment.
Multiple Safeguards
Directional Ventilation: Internal airflow design creates negative pressure, controlling airflow during the experiment.
Negative Pressure System: Equipped with removable HEPA filters at exhaust points for effective air filtration.
HEPA Filtration: Ensures clean air in the laboratory.
UV Disinfection: Two ozone UV disinfection lamps are installed to disinfect the chamber after experiments.
Shorter Fixed Travel: Movement components only operate within the sample area, optimizing cover opening time and fixed travel.
Monitoring Alerts: If consumables are not loaded correctly, the preparation interface will display an alert icon.